• Medium voltage Fixed Capacitor Banks
  • Medium voltage Automatic Capacitor Banks
  • Medium voltage Detuned Capacitor Banks
  • Medium voltage Harmonic Filter
  • Multiple Tuned Filters
  • High Pass Filters

click on the images to view full size

FEATURES AND SPECIFICATIONS

ENCLOSURES
- 11 Gauge, SEAM welded NEMA 1, 3R or 4X ratings

- Outdoor units consist of galvanized steel.

-C-Channel base is supplied for rigidity and skidding into place.

-ANSI gray-61 corrosion resistant enamel

-Continuous 1/4"x2" ground bus is also included.

-Heavy-duty 3-point latching mechanism with rollers

-Stainless steel continuous hinge and fastening hardware inside and out.

-Aluminum or galvanized steel nameplates and warning labels blind riveted to enclosure.

-Forced air ventilation.

 

CAPACITORS

 

- 95kV BIL rating, low loss, single bushing, all-film capacitors.

-Ungrounded Y- configuration switched in specified kvar increments.

-Stainless steel tank and mounting brackets with a light gray finish.

-Meet the latest applicable ANSI / IEE and NEMA standards.

- Non-PCB dielectric fluid

-Internal discharge resistors

 

PROTECTION AND PROTECTION CHEMES

 

- 50kA curent limiting fuses

-Blown fuse detection and phase unbalance schemes. Y grounded with potential transformer, *Y ungrounded with current transformer in ground correction , *Double-Y connected.

-Control power transformer with both primary and secondary current limiting fuses.

 

OPTIONS
- Externally operated air disconnect or load interrupting switch. *fuses, non-fused, shunt-trip, rated for capacitive current interruption.

- Mechanically interlocked ground switch

-Oil or vacuum switches for switching the cpacitor kvar steps on and off.

-Surge arrestors for vacuum switched harmonic filters

-Kirk Key interlock systems

- Transient inrush reactors

 

POWER FACTOR CONTROLLERS
The capacitor banks are equipped with a digital power factor controller. The controller has a digital display that shows plant power factor, plant current level and plant voltage level. Set point power factor is set by digital display.
 

REACTORS

 

Reactors are designedspecifically for each application and include:

- Standard iron core design.

- Air core reactors based on application requirements.

-3 Phase reactors up to 4.16kV.

-Single phase reactors at higher voltages.

- Reactors for de-tuned and harmonic filter banks are supplied with insulation levels in acordance with harmonic loads.


SPECIFICATION

 



 



 

 

 

 

 

 

 