Capacitor Banks
FIXED (STATIC) CAPACITOR BANK
PowerCap - Low Voltage
Capacity
  • 2 kvar – 400 kvar
Network Voltage
  • 208v – 600v
  • Other Voltages Available
Type
  • Oil or dry
Phase
  • 1 or 3PH
  • Other Voltages Available
Options
  • Contactor
  • External Fuses
  • Blown Fuse Indicator

Built to CSA, UL and IEEE standards.
The above equipment will bear a CSA/UL logo.

PowerCap - Medium Voltage
Capacity
  • 25 kvar and above
Network Voltage
  • 2400v – 35kV
Type
  • Oil
Phase
  • 3PH
Options
  • NEMA/EEMAC 12 & 3R Enclosure
  • Main Breaker
  • Disconnect Switch
  • Fuse Disconnect Switch
  • Ground Switch
  • Unbalance Protection
  • Others
AUTOMATIC CAPACITOR BANK
PowerVar - Low Voltage
Capacity
  • 50kvar - 1200kvar
Network Voltage
  • 208v – 600v
  • Other Voltages Available
Options
  • NEMA/EEMAC 12 & 3R Enclosure
  • Main Breaker
  • Disconnect Switch
  • Fuse Disconnect Switch
  • Blown Fuse Indicators
  • Capacitor Life Indicators
PowerVar - Medium Voltage
Capacity
  •  25kvar and above
Network Voltage
  • 2400v – 35kV
Options
  • NEMA/EEMAC 12 & 3R Enclosure
  • Main Breaker
  • Fuse Disconnect Switch
  • Ground Switch
  • Unbalance Protection
  • Others
   Built to CSA, UL and IEEE standards.
   The above equipment will bear a CSA/UL logo.
POLE MOUNT CAPACITOR BANK
Medium Voltage
Capacity
  • 150kvar and above
Network Voltage
  • Up to 35kv
Phase
  • 3PH
Options
  • Internal Fuses
  • Blown Fuse Indicators
  • Unbalance Protection
  • Disconnect Switch
  • Ground Switch
  • Others

These banks are pre-wired, factory assembled and shipped ready for installation. Banks are fixed or switch type and utilize all-film, single phase capacitors connected for three-phase operation.

This is an ideal solution when physical space for a capacitor banks is limited.

   Built to CSA, UL and IEEE standards.
   The above equipment will bear a CSA/UL logo.
RACK/STRUCTURE CAPACITOR BANK
Medium Voltage
Capacity
  • 150kvar and above
Network Voltage
  • 2400v and above
Phase
  • 3PH
Options
  • Internal Fuses
  • Blown Fuse Indicators
  • Unbalance Protection
  • Disconnect Switch
  • Ground Switch
  • Others
   Built to CSA, UL and IEEE standards.
   The above equipment will bear a CSA/UL logo.
PAD MOUNT CAPACITOR BANK
Medium Voltage
Capacity
  • 150kvar and above
Network Voltage
  • Up to 25kv
Phase
  • 3PH
Options
  • Internal Fuses
  • Blown Fuse Indicators
  • Unbalance Protection
  • Disconnect Switch
  • Ground Switch
  • Others

Power Survey “Pad Mount” capacitor banks are designed for application within utility distribution systems and areas that are accessible to the public.  These capacitor banks have a low profile, are compact and are usually painted green to blend in with their surroundings (outside environments).

Built to CSA, UL and IEEE standards.
The above equipment will bear a CSA/UL logo.

ZERO VOLTAGE CROSSING OR PRE-INSERTION AUTOMATIC CAPACITOR BANK
Capacity
  • 100kvar and above
Network Voltage
  • 2400v – 69kV
Phase
  • 3PH
Options
  • Internal Fuses
  • Blown Fuse Indicators
  • Unbalance Protection
  • Disconnect Switch
  • Ground Switch
  • Others

Power Survey Zero Voltage Crossing (ZVC) capacitor bank is a state-of-the-art microprocessor based control.  The purpose of the ZVC system is to virtually eliminate capacitor energizing transients by independently energizing each phase of the capacitor bank coincident with the occurrence of the phase’s zero system voltage reference point.

The expected benefits include:

  • Increased “power quality” by utilizing capacitor switching with significantly reduced voltage spikes which are a nuisance to sensitive equipment such as computers and adjustable speed drives.
  • Increased capacitor and switch life.
  • Reduction of induced voltages into the low voltage control wiring.
  • Reduction of station ground transients and reduction of distribution ground transients.
   Built to CSA, UL and IEEE standards.