FIXED (STATIC) HARMONIC FILTER
PowerCap Filter - Low Voltage
| Capacity |
|
|
| Network Voltage |
- 208v – 600v
- Other Voltages Available
|
| Options |
- NEMA/EEMAC 12 & 3R Enclosure
- Main Breaker
- Disconnect Switch
- Fuse Disconnect Switch
- Blown Fuse Indicators
|
Built to CSA, UL and IEEE standards. The above equipment will bear a CSA/UL logo.
PowerCap Filter - Medium Voltage
| Capacity |
|
|
| Network Voltage |
- 2400v – 35000v
- Other Voltages Available
|
| Type |
|
|
| Phase |
|
|
| Options |
- NEMA/EEMAC 12 & 3R Enclosure
- Main Breaker
- Disconnect Switch
- Fuse Disconnect Switch
- Ground Switch
- Unbalance Protection
- Others
|
AUTOMATIC CAPACITOR BANK AND HARMONIC FILTER
PowerVar Filter - Low Voltage
| Capacity |
|
|
| Network Voltage |
- 208v – 600v
- Other Voltages Available
|
| Options |
- NEMA/EEMAC 12 & 3R Enclosure
- Main Breaker
- Disconnect Switch
- Fuse Disconnect Switch
- Blown Fuse Indicators
- Capacitor Life Indicators
|
PowerVar Filter - Medium Voltage
| Capacity |
|
|
| Network Voltage |
- 2400v – 35kV
- Other Voltages Available
|
| Options |
- NEMA/EEMAC 12 & 3R Enclosure
- Main Breaker
- Disconnect Switch
- Fuse Disconnect Switch
- Ground Switch
- Unbalance Protection
- Others
|
Built to CSA, UL and IEEE standards. The above equipment will bear a CSA/UL logo.
"REAL TIME/FAST SWITCHING" THYRISTOR SWITCHED AUTOMATIC HARMONIC FILTER BANK
Dynamic PowerVar Filter
| Applications – Rapid Power Factor Correction and Harmonic Filtering for: |
- Spot Welders
- DC Drives
- Windmill Plants
- Lifts and Cranes
- Any Other Rapid Varying Load
|
|
| Capacity |
|
|
| Network Voltage |
|
|
| Phase |
|
|
| Options |
- NEMA/EEMAC 12 & 3R Enclosure
- Main Breaker
- Disconnect Switch
- Fuse Disconnect Switch
- Blown Fuse Indicator
- Capacitor Life Indicator
|
|
Built to CSA, UL and IEEE standards. The above equipment will bear a CSA/UL logo.
RACK/STRUCTURE HARMONIC FILTER
Medium Voltage
| Capacity |
|
|
| Network Voltage |
|
|
| Phase |
|
|
|
| Options |
- Internal Fuses
- Blown Fuse Indicators
- Unbalance Protection
- Disconnect Switch
- Ground Switch
- Others
|
|
Built to CSA, UL and IEEE standards. The above equipment will bear a CSA/UL logo.
ZERO VOLTAGE CROSSING OR PRE-INSERTION AUT. HARMONIC FILTER AND CAPACITOR BANK
Medium Voltage
| Capacity |
|
|
| Network Voltage |
|
|
| Phase |
|
|
| Options |
- Internal Fuses
- Blown Fuse Indicators
- Unbalance Protection
- Disconnect Switch
- Ground Switch
- Others
|
Power Survey Zero Voltage Crossing (ZVC) capacitor bank is a state-of-the-art microprocessor based control. The purpose of the ZVC system is to virtually eliminate capacitor energizing transients by independently energizing each phase of the capacitor bank coincident with the occurrence of the phase’s zero system voltage reference point.
The expected benefits include:
- Increased “power quality” by utilizing capacitor switching with significantly reduced voltage spikes which are a nuisance to sensitive equipment such as computers and adjustable speed drives.
- Increased capacitor and switch life.
- Reduction of induced voltages into the low voltage control wiring.
- Reduction of station ground transients and reduction of distribution ground transients.
Built to CSA, UL and IEEE standards. The above equipment will bear a CSA/UL logo.
|